R3 Interface
TECHNICAL SPECIFICATIONS

Model 2002E Simplex serial Interface
Model 2022E Multiplex serial Interface

  • Full-duplex, asynchronous data stream RS-232-C, RS-422-A, configured DTE
    Stop and parity bits selectable
    110-19,200 baud rate
  • Three Operating Modes:
    Mode 1 Direct Single Report upon read
    Mode 2 Polled for read data
    Mode 3 Direct Multiple Report upon read
  • Buffered read storage:
    4 readings for the 2002E, 2 reading for the 2022E
  • Protocols and modes selectable through commands or via pins and shunts on PCB
  • Many other commands available
  • Connectors DB-25S, DIN 41612 Type C
  • Control Signals DSR, CTS, DTR
  • Compatible to all Readers, wired via twisted pair
  • Temperature range: -40 to +55 degrees C operating
    -55 to +85 degrees C non-operating
  • Power: 2002E = 5VDC (+/-5%) @ 250 mA maximum
    2022E = 5VDC (+/-5%) @ 350 mA maximum
  • CRC algorithm allows 1 in 10 to the 14th errors

All information copyright 1999 RFID, Inc.
For information, contact: RFID, Inc. • 3538 Peoria Street, unit 505 • Aurora, CO 80010
phone (303)366-1234 • fax (303)366-1222 • email info@rfidinc.com